ID 100B/1.4
The TROVAN ID-100B/1.4 Mini Transponder is designed for applications where a small, unobtrusive ID tag is called for. This configuration is suitable for large-scale animal applications (for example fish hatcheries) requiring smallest-size transponders and/or extended exposure to fluids. Each ID-100B/1.4 Mini Transponder ID numbers are fixed during manufacture, and cannot be altered by third parties. The code uniqueness is protected by patent. Each transponder is encapsulated in special, biocompatible glass, individually pre-sterilized and packaged in a bubble pack. It comes ready for application, in its own disposable needle and with 6 ea. adhesive labels featuring the ID code in human readable (alpha-numeric) and barcode 39 format.
SUGGESTED ADDITIONAL EQUIPTMENT
IM-100/1.4 Syringe style implanter
TRANSPONDER
DIMENSIONS
Length: 8.2 ± 0.03 mm (0.32 in.)
Diameter: 1.4 ± 0.10 mm (0.06 in.) WEIGHT
30 ± 6 mg
IDENTIFICATION CODE
64 bits, factory pre-programmed ENCAPSULATION
Biocompatible glass SCAN ANGLE
Spherical
STORAGE TEMPERATURE (tested exposure 1 hour)
-40˚C to +140˚C (-40˚F to 284F) OPERATING TEMPERATURE
-20˚C to +75˚C (-4˚F to 167˚F) OPERATING FREQUENCY
128 kHz ENVIRONMENT
IP68 MECHANICAL PRESSURE
Axial max. 10N Radial max. 40N
VIBRATION
Random -20 to 2,000 Hz/10 g./1 hr. p. axis Sine -20 to 2,000 Hz/5 g/1 hr. p. Axis
READING RANGE
GR-250 up to 17 cm (6.7 in.)
NEEDLE
DIMENSIONS
Length: 32 mm (1.26 in.)
Outside dia.: 2 mm (0.08 in.)
PRESENTED BY: Locus Technology, Inc. 3989 Rupp Rd., Manchester, MD 21102, USA
U.S. Patent Nos. 5,084,699; 5,223,851; 5,281,855. Addt’l U.S. and overseas patents pending